SWS BL–C BOLT Load Cell

SWS BL–C BOLT Load Cell

With continuous monitoring, it is a lot easier to determine the bolt load while the load cell is mounted, at any time. In addition to checking the bolt load at any given time, it is also possible to view historical data. This helps to determine when and where a problem with the bolt load might have occurred. where data from all sensors can be monitored RS-232 and Analog Converter . The live data from the bolt load cells can be checked remotely with different readout methods.

Features

Sizes To fit bolt sizes from M20 to M72
Cable lengths Standard: 1 meter (optionally 5 or 10 meter)
Full Scale Load (FS) From 166 kN to 2500 kN depending on sensor size
Maximum Load at ambient temperature FS range x 1.3 (without affecting the validity of the calibration)
Temperature range -40°C to 80°C
Minimum Load 10% FS
Total accuracy at ambient temperature (rms) < 5 % FS (machined parallel surfaces in bolt-nut assembly)
Linearity < 1.5 % FS
Hysteresis < 0.9 % FS
Creep < 0.1 % FS
Repeatability < 0.5 % FS
Typical Temperature effects < ± 0.08 % FS/°C
Sealing IP66
Material Tool Steel
Sensor Output MV
Power Supply Powered through electronic interface  Maximum 12 v DC
Connection M12 connector male 5 pole